Basic Info
Model NO. | MZ(LBS)34-12/630A M |
Operation | Manual Electric |
Grounding Mode | Grounding |
Movement Mode | Horizontal Rotary Type |
Number of Poles | Three Pole |
Series | Three |
Run | Swing |
Switching Mode | Double-Throw Type |
Common Model | Pgs-630A |
Structure of Operating | Electric |
Certification | ISO, GS, RoHS, CE, IS9001, ISO9001, ISO9002, ISO2000 |
Brand | Mingzhe |
Rated Voltage | 12kv 24kv 40.5kv |
Rated Current | 630A 400A |
Switch | Sf6 Pole Mounted Lbs |
Withstand Current | 25ka |
Protecting Type | Conventional Circuit Breaker, Circuit-Breaker Fail |
Mechanical Life | 10000times |
Transport Package | Pallet Wooden |
Specification | 600x900x2000 |
Trademark | MINGZHE |
Origin | China |
HS Code | 8535299000 |
Production Capacity | 500PCS/Week |
Product Description
24kv 36KV /400A-20ka Outdoor Pole Mounted Sf6 Gas Insulated Load Break Switch (LBS)SummaryPole-mounted load break switch(pole-LBS) applies up to 36KV 400/630A, 50Hz pole-LBS associated with a state of the art controller. This SF6 gas-insulated switch can corporate with the distribution automation system, and also isolate a faulted section of distribution line from the control center.A simple pole-mounting arrangement contribute to quick and low cost installation, and the switch can be operated manually with a electronic controller. Electronic controller is contained in a stainless steel cabinet for an all weather environmental conditions. Remote monitoring and control can also be provided mounting wire or wireless modem in a cabinet.Standard service conditionIt shall be principal that this SF6 Gas Load Break Switch shall be used in the following service condition:Ambient temperatureShort period peak value:50ºCAverage over a period of 24 hours: 40ºCLower limit over 24 hours: -25ºCRelative humidity: 100%Maximum altitude:1,000 meterFeatures
- rugged switch
- drivepipe with large diversity
- quick operation
- inflation valve
- high pressure relief alarm
- HD gas-pressure meter
- Manual locking device
- Low pressure warning device
- Visible open/close status
- Cintact position indicator
- Manual operation on ground
- To provide one-stop service, please consult!
Detailed PhotosProduct Parameters
Product mode | | FLW34-12/630A | FLW34-24/630A | FLW34-36/630A |
Rated voltage | KV | 12 | 24 | 36 |
6/12/17.5 | 25.8 | 36 |
Rated frequency | Hz | 50/60 | 50/60 | 50/60 |
Lightning impulse withstand voltage | KV | 110 | 125 | 200 |
Power frequency withstand voltage 1min | Dry | KV | 50 | 75 | 110 |
wet | 40 | 60 | 95 |
Rated current | A | 400/630 |
Peak withstand current | KA | 50 | 50 | 50 |
Rated short time making current | KA | 20 | 20 | 20 |
Rated short time withstand current | KA/S | 4./20 | 4./20 | 4./20 |
Rated cable charging breaking current | A | 10 | 16 | 20 |
Rated line charging breaking current | A | 1 | 1.5 | 2 |
Rated closed-loop breaking current | A | 400/630 |
Rated current breaking times | Times | ≥400 |
Rated working pressure | Mpa | 0.05 |
Per-phase main circuit resistance | uΩ | ≤80 |
Relative gas leakage rate | Year | ≤1% |
Operation of mechanical stability | Times | 6000 |
weight | kg | 115 | 125 | 135 |
Institutions boxes and controller protection class | IP67 |
Type of mounting | The lifting type(suspended)/block(horizontal) |