Category
Fln36-12 10kv 11kv 12kv Sf6 Load Break Switch in High Voltage Rmu Switchgear Accessories 2023
FLN36-12 10kv 11kv 12KV SF6 Load Break Switch in High Voltage RMU Switchgear Accessories Summary:FLN36/48- 12D/T630-25 i
Basic Info
Model NO. | FLN36-12 |
Breaking Capacity | High Voltage Circuit Breakers |
Operation | Manual Type |
Speed | Normal Type Circuit Breaker |
Arc-extinguishing Medium | SF6 |
Installation | Fixed |
Structure | Lbs |
Certification | ISO9001-2000 |
Voltage | 12kv |
Current | 630A |
Frequency | 50Hz |
Phase Distance | 210mm |
Altitude | Not Higher Than 2000m |
Transport Package | Standard Export Shipping Package |
Trademark | LIYOND |
Origin | Zhejiang, China |
Production Capacity | 1000 Pieces/Month |
Product Description
FLN36-12 10kv 11kv 12KV SF6 Load Break Switch in High Voltage RMU Switchgear AccessoriesSummary:FLN36/48- 12D/T630-25 indoor AC high voltage SF6 load switch and FLRN36/48- 12D/T1250-31.5 indoor AC high voltage SF6 load switch fuse combination apparatus is suitable for three-phase 50Hz ring network or terminal power supply and industrial electrical equipment, for protecting the line of 10kV Electric Power Load Control System.The load switch can be divided into load current, closed loop current, no-load transformer and cable charging current;The combined apparatus is capable of breaking any current which is reach to rated short circuit, and is suitable for the electrical equipment of the ring network unit, the box type substation and so on.The utility model is especially suitable for places such as the distribution of the urban residential areas, the small two substations, the opening and closing stations, the industrial and mining enterprises, large shopping malls, airports, subways, hospitals, stadiums, etc.Ambient condition:
1.Altitude: ≤2000m2.Ambient temperature: -40°C ~+40°C3.Earthquake intensity: ≤8 degree4.Relative humidity: Daily averages ≤95%, Monthly average≤90%
Parameters:
Item | Unit | Data | |||
FLN48-12D/T630-25 | FLRN48-12D/T1250-31.5 | ||||
Rated voltage | kV | 12 | |||
Rated frequency | Hz | 50 | |||
Rated current | A | 630 | 1250 | ||
Rated active load breaking current | 630 | ||||
Rated closed loop dropout current | 630 | ||||
Rated transfer current | 1700 | ||||
Lightning impulse withstand voltage(peak) | kV | phase to earth, between phase 75, fracture 85 | |||
1 min power frequency withstand voltage | phase to earth, between phase 42, fracture 48 | ||||
Rated short-time withstand current(2s) | kA | 25 | |||
Rated peak withstand current | 63 | ||||
Rated short-circuit closing current(peak) | 63 | 80(expected) | |||
Fuse type | S LAJ-12 | ||||
Output energy of impactor | J | 1+0.5 | |||
Mechanical life | Load switch | times | 5000 | ||
Earth switch | 2000 |
More types:
FAQ:
Q: Could I have prices of your products?
A: Welcome. Please feel free to send us inquiry here. We will reply you within 24 hours.
Q: Can I get a sample before the bulk order?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q: Can we print our logo/ company name on products?
A: Yes, of course, we accept OEM, then need you to provide brand authorization to us.
Q:Do you accept product customization?
A:Yes, of course, please provide specific drawings or parameters, we will quote you after evaluation.
Q: What is the lead time?
A: The lead time depends on the quantities ordered, generally within 7-20 days after receiving the payment.
Q: What is your Trade Terms?
A: We accept EXW, FOB, CIF, FCA, etc.
Q: What is your payment method?
A: We accept T/T, Western Union, Paypal, etc.
Q: Do you inspect the finished products?
A: Yes, each step of production and finished products will be came out inspection by QC department before shipping. And we will provide goods inspection reports for your reference before shipment
Q: How to solve the quality problems after sales?
A: Take photos of the quality problems and send to us for our checking and confirming, we will make a satisfied solution for you within 3 days.