Indoor 36kv High Voltage Sf6 Gas Load Break Switch

Indoor 36kv High Voltage Sf6 Gas Load Break Switch

Warmly wecome to Send us any enquiries anytime" We focus on every detail GSC-36, Completely under IEC international stan
Basic Info
Model NO. GSC-SC6
Withstand Current 20ka,16ka
Rated Voltage 36kv
Rated Current 630A
Rated Frequency 50/60Hz
Standard IEC,ANSI,Ceb,GB
Transport Package Wooden, Carton
Specification Phase distance 350mm(36kV)
Trademark GRENO
Origin Xia Men
Production Capacity 1500sets/Month
Product Description
Warmly wecome to Send us any enquiries anytime"

 

We focus on every detail

 

GSC-36,
Completely under IEC international standard and GB standard.
Arc-extinguishing and insulation by SF6 gas.
Especially suitable for secondary distribution.

Indoor 36kv High Voltage Sf6 Gas Load Break Switch

Indoor 36kv High Voltage Sf6 Gas Load Break Switch

Indoor 36kv High Voltage Sf6 Gas Load Break Switch

Indoor 36kv High Voltage Sf6 Gas Load Break Switch

Indoor 36kv High Voltage Sf6 Gas Load Break Switch


++++ Main technical specifications
Item NO.NameUnitTechnical parameters
Load break switch panel
1Rated Voltage UnkV122436
2Rated FrequencyHz505050
3Rated CurrentA630630630
4Rated Load Breaking CurrentA630630630
5Rated Short Time Withstand Current(rms)kA202020
6Rated Short Time Durations333
7Rated Peak Withstand Current kA505050
8Rated Closed Switch - Off CurrentA630630630
9Rated Cable Charging Breaking CurrentA101010
10Rated Active Load Breaking CurrentA630630630
13Earthing Switch 2s Short Time Withstand Current kA202020
14Rated Short-Circuit Current Making Times times222
15Rated Current Breaking Timestimes101010
16Mechanical Endurance Load Break Switchtimes300030003000
Earthing Switchtimes200020002000
17SF6 gas anual leakage rate≤ /year0.10%0.10%0.10%
18Rated Insulation LevelUnitTechnical parameters
1min Power Frequency withstand voltage(rms)On isolating distancekV4860110
Phase to Phase kV425085
Phase to EarthkV425085
Lightning impulse withstand voltage(peak)On isolating distancekV85145215
Phase to Phase kV75125185
Phase to EarthkV183184185
Note: For short circuit breaking and peak current is based on Fuse plus combination.
Our Services
12 months warranty
Type test, technical and marketing support.
Warmly welcome customized design.
After-sales service ..

1.What is the payment term?
T/T, wire transfer, west union
2. What kind of VCB do you have?
We have 12kv,24kv,36kv,40.5kv lateral type and withdrawable type vacuum circuit breaker.
3. Warranty period?
Normally 12 months.
3.How about type test?
Our client passed type test in Europe, and we also type tested in China.