Model NO. VS1-24
Poles Number 3
Type Circuit Breaker
Function Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, Do as Your Request
Certification ISO9001-2000, CE
Rated Voltage 24kv
Rated Frequency 50/60Hz
Rated Current 630A/1250A/1600A/2000A/2500A/3150A/4000A
Phase Distance 150mm/210mm/275mm
Transport Package Wooden Case
Specification steel, expoxy resin
Trademark LIYOND
Origin China
HS Code 8535210000
Production Capacity 3000/Month
Product Description

Vs1-24kv 630A 1250A Indoor Vs1 Zn63 Vcb Front Mounted Vacuum Interrupters for Distribution Switchgear

VS1-24kV 630A 1250A Indoor VS1 ZN63 VCB Front Mounted vacuum interrupters for distribution switchgear

Summary

VS1-24 Indoor High Voltage Vacuum Circuit Breaker is three-phase AC 50Hz, Rated voltage of 24kV indoor device, For industrial and mining enterprises, power plants and substations as electrical equipment control and protection purposes, and for frequent operation of the place.

VS1 type vacuum circuit breaker conforms to national standard GB1984-2003 HV Vacuum Circuit Breaker, JB3855-1996<3.6-40.5kV indoor AC high voltage vacuum circuit breaker>, DL/T403-2000<12kv-40.5kv HV vacuum circuit breaker ordering technical conditions>, and IEC62271-100:2001 high voltage AC circuit breaker relevant regulations.

Applying Ambient Conditions

1.Ambient temperature: -25ºC- +40ºC
2.The height above sea level: ≤1000 m
3.Relative humidity: the average humidity of a day should be no more than 95%; the average humidity of a month should be no more than 90%.
4.Saturated vapor pressure: the average pressure of a day should be no mare than 2.2kPa; the average pressure of a month should be no more than1.8KPa, when the temperature drops sharply, it may condense.
5.Earthquake intensity: not exceed 8 degrees
6.It should be Installed in the places without fire, explosion, serious pollution, chemical erosion and violent vibration.

Main technical parameters

NO.ItemUnitData
1Rated voltage KV24
2Rated insulation level 1min power frequency withstand voltageKV42
3Rated insulation level rated lighting impulse withstand voltageKV75
4Rated currentA630/1250/1600/2000/3150/4000
5Rated short circuit breaking currentKA20/25
6Rated short-circuit opening and closing current(peak)KA50/63
7Rated dynamic current(peak)KA50/63
8Rated thermal stability current(rms)KA20/25
9Rated short circuit current breaking timestime50,20
10Rated thermal stability times4
11Rated operating sequence/O-0.3S-CO-180S-CO
12Mechanical lifetime10000
13Rated single capacitor bank breaking currentA630
14Rated back to back capacitor bank breaking currentA400

Vs1-24kv 630A 1250A Indoor Vs1 Zn63 Vcb Front Mounted Vacuum Interrupters for Distribution Switchgear

Vs1-24kv 630A 1250A Indoor Vs1 Zn63 Vcb Front Mounted Vacuum Interrupters for Distribution Switchgear

Vs1-24kv 630A 1250A Indoor Vs1 Zn63 Vcb Front Mounted Vacuum Interrupters for Distribution Switchgear

Vs1-24kv 630A 1250A Indoor Vs1 Zn63 Vcb Front Mounted Vacuum Interrupters for Distribution Switchgear

 


FAQ

Q: Could I have prices of your products?

A: Welcome. Please feel free to send us inquiry here. We will reply you within 24 hours.

Q: Can I get a sample before the bulk order?

A: Yes, we welcome sample order to test and check quality.Mixed samples are acceptable.

Q: Can we print our logo/ company name on products?

A: Yes, of course, we accept OEM, then need you to provide brand authorization to us

Q:Do you accept product customization?

A:Yes, of course, please provide specific drawings or parameters, we will quote you after evaluation

Q: What is the lead time?
A: The lead time depends on the quantities ordered, generally within 7-20 days after receiving the payment.

Q: What is your Trade Terms?
A: We accept EXW, FOB, CIF, FCA, etc.

Q: What is your payment method? A: We accept T/T, Western Union, Paypal, irrevocable L/C at sight, etc

Q: Do you inspect the finished products?

A: Yes, each step of production and finished products will be came out inspection by QC department before shipping. And we will provide goods inspection reports for your reference before shipment

Q: How to solve the quality problems after sales?
A: Take photos of the quality problems and send to us for our checking and confirming, we will make a satisfied solution for you within 3 days.