banner
Home / Products / MV Products
Products
EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination

EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination

MV Inside Cone Plug-in Separable Connector up to 52kV GCA MV inside cone plug-in separable connector suitable for the co
Basic Info
Model NO. CBN35-1#, CBN35-2S#, CBN35-3#
Interface Type 1#, Type 2S#, Type 3#(EN50181)
Voltage 12kV, 17.5kV, 24kV, 36kV, 40.5kV, 52kV
Manufacture Experience >20years
Cross section range 35-630mm2
Cable Shield Style Copper Wire, Copper Tape
Number of Cores 1, 3
Type Tested Yes
Transport Package Carton Box
Trademark GCA
Origin China
HS Code 8546900000
Production Capacity 1000000PCS/Year
Product Description

MV Inside Cone Plug-in Separable Connector up to 52kV

GCA MV inside cone plug-in separable connector suitable for the connection between XLPE insulation power cable and the electric equipments which equipped with inside cone socket/bushing designed in accordance with EN 50180, EN 50181 and DIN 47637, such as switchgear, transformer and cable junction box etc.CBN35-1# suit for connecting with size 1 socket (bushing) which is designed in accordance with EN 50180, EN 50181 and DIN 47637.CBN35-2S# suit for connecting with size 2 socket (bushing) which is designed in accordance with EN 50180, EN 50181 and DIN 47637.CBN35-3# suit for connecting with size 3 socket (bushing) which is designed in accordance with EN 50180, EN 50181 and DIN 47637.Electrical specification according to standard of IEC 60502-4, IEC60840, CENELEC HD 629.1 S2.Widely used in various regions, especially fire forbidden area, high altitude, cold weather, high-humidity, salt-fog and heavy polluted regions. Reusable, easy maintenance.


EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination


Specification
EN50181 standard size GCA size Cable voltage Diameter over XLPE insulation Cable conductor size
1#, Um = 36 kV, Ir = 630 A 1#, Um = 40.5 kV, Ir = 630 A 12kV, 17.5kV, 24kV, 36kV, 40.5kV Ø14.7~Ø34.5 mm ≤70 mm2
2#, Um = 36 kV, Ir = 800 A 2S#, Um = 40.5 kV, Ir = 800 A 12kV, 17.5kV, 24kV, 36kV, 40.5kV Ø14.7~Ø43.1 mm 35~300 mm2
3#, Um = 52 kV, Ir = 1250 A 3#, Um = 52 kV, Ir = 1250 A 12kV, 17.5kV, 24kV, 36kV, 40.5kV, 52kV Ø14.7~Ø53.1 mm 35~630 mm2

Application

CBN35 in cable junction box installed in Tibet railway CBN35 separable connector installed in transformer

CBN35 separable connector installed in AREVA C-GIS CBN35 installed in ABB switchgear

CBN35 installed in cable junction box CBN35 installed in SIEMENS switchgear

 

EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination

EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination

EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination

EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination